CVE-2026-94142
A security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200.
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (0.18%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
A security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200. Affected by this vulnerability is the function sub_1105C of the file BS_HWMIO64_W10.sys of the component IOCTL Handler. Such manipulation of the argument PhysicalAddress leads to write-what-where condition. The attack needs to be performed locally. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
- CVSS 4.0
- 8.5 HIGHCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/M
- EPSS
- 0.18% probability · 5th percentile
- Public exploits
- None in Exploit-DB
- CISA KEV
- Not listed
- Weakness
- CWE-119, CWE-123
- Source
- cna@vuldb.com
EPSS moved from 0.1% on 21 September 2026 to 0.2% on 27 November 2026.