CVE-2026-8033
A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7.
Does this matter?
Lower severity and a low EPSS score (0.48%). Track it; it rarely justifies an emergency change on its own.
Description
A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
- CVSS 4.0
- 5.5 MEDIUMCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/M
- EPSS
- 0.48% probability · 34th percentile
- Public exploits
- None in Exploit-DB
- CISA KEV
- Not listed
- Weakness
- CWE-200, CWE-284
- Source
- cna@vuldb.com
EPSS 0.5% since 27 November 2026; no change recorded yet. Points are recorded when the score first appears and whenever it moves by a percentage point or more.
References
Source: NVD record, EPSS from FIRST.org, KEV from CISA, exploits from Exploit-DB. Refreshed daily. Download this record as JSON.