CVE-2019-25678
C4G Basic Laboratory Information System 3.4 contains multiple SQL injection vulnerabilities that allow unauthenticated attackers to execute arbitrary SQL commands by injecting malicious code through the site parameter.
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (0.27%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
C4G Basic Laboratory Information System 3.4 contains multiple SQL injection vulnerabilities that allow unauthenticated attackers to execute arbitrary SQL commands by injecting malicious code through the site parameter. Attackers can send GET requests to the users_select.php endpoint with crafted SQL payloads to extract sensitive database information including patient records and system credentials.
- CVSS 4.0
- 8.8 HIGHCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/M
- EPSS
- 0.27% probability · 20th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-306, CWE-89
- Affected
- gatech/computing for good\'s basic laboratory information system
- Source
- disclosure@vulncheck.com
References
- https://www.exploit-db.com/exploits/46438Exploit, VDB Entry
- https://www.vulncheck.com/advisories/c4g-blis-sql-injection-via-users-select-phpThird Party Advisory
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.