SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityDeferred

CVE-2026-5768

The Frontier X2 device allows unauthenticated BLE read/write access to critical GATT characteristics without enforcing pairing authentication or authorization.

HIGH 8.8EPSS 0.28%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (0.28%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

The Frontier X2 device allows unauthenticated BLE read/write access to critical GATT characteristics without enforcing pairing authentication or authorization. This allows attackers within BLE range to perform unauthorized control of device functions, including starting/stopping activities, triggering vibrations, causing denial-of-service conditions, and fuzzing characteristic values to induce unexpected behavior. Additionally, the Frontier X mobile application lacks proper BLE device authentication, allowing attackers to impersonate a legitimate Frontier X2 device and connect to the application. By cloning BLE advertisements and exposing expected GATT characteristics, attackers can manipulate activity states and inject fabricated health telemetry such as breathing rate, heart rate, strain, and other health-related data into the mobile application.

CVSS 3.1
8.8 HIGHCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
0.28% probability · 20th percentile
CISA KEV
Not listed
Weakness
CWE-306
Source
ics-cert@hq.dhs.gov