SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityAwaiting Analysis

CVE-2026-25599

Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control…

MEDIUM 6.3EPSS 0.11%

Does this matter?

Lower severity and a low EPSS score (0.11%). Track it; it rarely justifies an emergency change on its own.

Description

Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.

CVSS 3.1
6.3 MEDIUMCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L
EPSS
0.11% probability · 2th percentile
CISA KEV
Not listed
Weakness
CWE-79, CWE-306, CWE-319
Source
a6d3dc9e-0591-4a13-bce7-0f5b31ff6158

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.