CVE-2026-25599
Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control…
Does this matter?
Lower severity and a low EPSS score (0.11%). Track it; it rarely justifies an emergency change on its own.
Description
Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.
- CVSS 3.1
- 6.3 MEDIUMCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L
- EPSS
- 0.11% probability · 1th percentile
- Public exploits
- None in Exploit-DB
- CISA KEV
- Not listed
- Weakness
- CWE-79, CWE-306, CWE-319
- Source
- a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
EPSS 0.1% since 27 October 2026; no change recorded yet. Points are recorded when the score first appears and whenever it moves by a percentage point or more.
References
Source: NVD record, EPSS from FIRST.org, KEV from CISA, exploits from Exploit-DB. Refreshed daily. Download this record as JSON.