SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityAnalyzed

CVE-2025-5862

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical.

HIGH 7.4EPSS 0.99%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (0.99%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0
7.4 HIGHCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/M
EPSS
0.99% probability · 61th percentile
CISA KEV
Not listed
Weakness
CWE-119, CWE-120
Affected
tenda/ac7 firmware
Source
cna@vuldb.com

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.