CVE-2025-52586
This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry,…
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (0.08%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.
- CVSS 4.0
- 7.5 HIGHCVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/M
- EPSS
- 0.08% probability · 0th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-319
- Source
- ics-cert@hq.dhs.gov
References
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.