CVE-2025-40594
A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2).
Does this matter?
Lower severity and a low EPSS score (0.21%). Track it; it rarely justifies an emergency change on its own.
Description
A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.
- CVSS 4.0
- 6.9 MEDIUMCVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/M
- EPSS
- 0.21% probability · 11th percentile
- Public exploits
- None in Exploit-DB
- CISA KEV
- Not listed
- Weakness
- CWE-269
- Affected
- siemens/sinamics g220 firmware · siemens/sinamics s200 firmware · siemens/sinamics s210 firmware
- Source
- productcert@siemens.com
EPSS 0.2% since 27 October 2026; no change recorded yet. Points are recorded when the score first appears and whenever it moves by a percentage point or more.
References
Source: NVD record, EPSS from FIRST.org, KEV from CISA, exploits from Exploit-DB. Refreshed daily. Download this record as JSON.