SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityAnalyzed

CVE-2025-36546

On an F5OS system, if the root user had previously configured the system to allow login via SSH key-based authentication, and then enabled Appliance Mode; access via SSH key-based authentication is still allowed.

CRITICAL 9.2EPSS 0.42%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (0.42%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

On an F5OS system, if the root user had previously configured the system to allow login via SSH key-based authentication, and then enabled Appliance Mode; access via SSH key-based authentication is still allowed. For an attacker to exploit this vulnerability they must obtain the root user's SSH private key.   Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.

CVSS 4.0
9.2 CRITICALCVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/M
EPSS
0.42% probability · 36th percentile
CISA KEV
Not listed
Weakness
CWE-863
Affected
f5/f5os-a · f5/f5os-c
Source
f5sirt@f5.com

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.