CVE-2025-22961
A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284).
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (0.40%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.
- CVSS 3.1
- 8.0 HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
- EPSS
- 0.40% probability · 33th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-200
- Source
- cve@mitre.org
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.