SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityDeferred

CVE-2025-22961

A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284).

HIGH 8.0EPSS 0.40%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (0.40%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.

CVSS 3.1
8.0 HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
EPSS
0.40% probability · 33th percentile
CISA KEV
Not listed
Weakness
CWE-200
Source
cve@mitre.org

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.