CVE-2025-15574
Attackers with the knowledge of the registration numbers can connect to the MQTT server and impersonate the dongle / inverters.
Does this matter?
Lower severity and a low EPSS score (0.18%). Track it; it rarely justifies an emergency change on its own.
Description
When connecting to the Solax Cloud MQTT server the username is the "registration number", which is the 10 character string printed on the SolaX Power Pocket device / the QR code on the device. The password is derived from the "registration number" using a proprietary XOR/transposition algorithm. Attackers with the knowledge of the registration numbers can connect to the MQTT server and impersonate the dongle / inverters.
- CVSS 3.1
- 6.5 MEDIUMCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
- EPSS
- 0.18% probability · 8th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-330
- Source
- 551230f0-3615-47bd-b7cc-93e92e730bbf
References
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.