CVE-2025-11784
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2.
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (0.37%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
- CVSS 4.0
- 8.5 HIGHCVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/M
- EPSS
- 0.37% probability · 31th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-121
- Affected
- circutor/sge-plc1000 firmware · circutor/sge-plc50 firmware
- Source
- cve-coordination@incibe.es
References
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.