CVE-2024-6814
NETGEAR ProSAFE Network Management System getFilterString SQL Injection Remote Code Execution Vulnerability.
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (2.09%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
NETGEAR ProSAFE Network Management System getFilterString SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Authentication is required to exploit this vulnerability. The specific flaw exists within the getFilterString method. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-23399.
- CVSS 3.1
- 8.8 HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- EPSS
- 2.09% probability · 81th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-89
- Affected
- netgear/prosafe network management system
- Source
- zdi-disclosures@trendmicro.com
References
- https://kb.netgear.com/000066232/Security-Advisory-for-SQL-Injection-on-the-NMS300-PSV-2024-0019Vendor Advisory
- https://www.zerodayinitiative.com/advisories/ZDI-24-901/Third Party Advisory, VDB Entry
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.