CVE-2024-3879
A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633).
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (1.45%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
- CVSS 3.1
- 8.8 HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- EPSS
- 1.45% probability · 72th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-121, CWE-787
- Affected
- tenda/w30e firmware
- Source
- cna@vuldb.com
References
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.mdBroken Link
- https://vuldb.com/?ctiid.260913Permissions Required, Third Party Advisory, VDB Entry
- https://vuldb.com/?id.260913Third Party Advisory, VDB Entry
- https://vuldb.com/?submit.312822Third Party Advisory, VDB Entry
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.mdBroken Link
- https://vuldb.com/?ctiid.260913Permissions Required, Third Party Advisory, VDB Entry
- https://vuldb.com/?id.260913Third Party Advisory, VDB Entry
- https://vuldb.com/?submit.312822Third Party Advisory, VDB Entry
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.