SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityAnalyzed

CVE-2024-2546

A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical.

HIGH 8.8EPSS 0.99%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (0.99%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1
8.8 HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS
0.99% probability · 61th percentile
CISA KEV
Not listed
Weakness
CWE-121, CWE-787
Affected
tenda/ac18 firmware
Source
cna@vuldb.com

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.