CVE-2024-11654
A vulnerability classified as critical has been found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118.
Does this matter?
EPSS puts the probability of exploitation in the next 30 days at 29.1%, higher than 98% of all known CVEs. Patch or mitigate before the next change window.
Description
A vulnerability classified as critical has been found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. This affects an unknown part of the file /admin/network/diag_traceroute6. The manipulation of the argument diag_traceroute6 leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
- CVSS 4.0
- 5.1 MEDIUMCVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/M
- EPSS
- 29.10% probability · 98th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-74, CWE-77
- Affected
- engeniustech/enh1350ext firmware · engeniustech/ens620ext firmware · engeniustech/ens500-ac firmware
- Source
- cna@vuldb.com
References
- https://k9u7kv33ub.feishu.cn/wiki/YrKfwHqLjijPeYkMTQfcdhrBnyg?from=from_copylinkExploit, Third Party Advisory
- https://vuldb.com/?ctiid.285975Permissions Required, VDB Entry
- https://vuldb.com/?id.285975Third Party Advisory, VDB Entry
- https://vuldb.com/?submit.446637Third Party Advisory, VDB Entry
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.