CVE-2024-10130
A vulnerability classified as critical was found in Tenda AC8 16.03.34.06.
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (1.03%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
- CVSS 4.0
- 8.7 HIGHCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/M
- EPSS
- 1.03% probability · 62th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-121
- Affected
- tenda/ac8 firmware
- Source
- cna@vuldb.com
References
- https://github.com/JohenanLi/router_vuls/blob/main/ac8v4/FUN_004a8838.mdExploit, Third Party Advisory
- https://vuldb.com/?ctiid.280918Permissions Required
- https://vuldb.com/?id.280918Permissions Required
- https://vuldb.com/?submit.422141Third Party Advisory
- https://www.tenda.com.cn/Product