CVE-2023-46283
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA…
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (0.91%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.
- CVSS 3.1
- 7.5 HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- EPSS
- 0.91% probability · 58th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-120
- Affected
- siemens/opcenter quality · siemens/simatic pcs neo · siemens/sinumerik integrate runmyhmi \/automotive · siemens/totally integrated automation portal
- Source
- productcert@siemens.com
References
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.