CVE-2023-4152
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication.
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (0.74%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.
- CVSS 3.1
- 7.5 HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- EPSS
- 0.74% probability · 53th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-22
- Affected
- frauscher/frauscher diagnostic system 101
- Source
- info@cert.vde.com
References
- https://cert.vde.com/en/advisories/VDE-2023-038/Third Party Advisory
- https://cert.vde.com/en/advisories/VDE-2023-038/Third Party Advisory
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.