Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication.

HIGH 7.5EPSS 0.98%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (0.98%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device.

CVSS 3.1
7.5 HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS
0.98% probability · 60th percentile
CISA KEV
Not listed
Weakness
CWE-22
Affected
frauscher/frauscher diagnostic system 101
Source
info@cert.vde.com