CVE-2023-1133
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default.
Does this matter?
EPSS puts the probability of exploitation in the next 30 days at 50.0%, higher than 99% of all known CVEs. Patch or mitigate before the next change window.
Description
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated attacker to remotely execute arbitrary code.
- CVSS 3.1
- 9.8 CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- EPSS
- 50.05% probability · 99th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-502
- Affected
- deltaww/infrasuite device master
- Source
- ics-cert@hq.dhs.gov
References
- http://packetstormsecurity.com/files/172799/Delta-Electronics-InfraSuite-Device-Master-Deserialization.html
- https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02Third Party Advisory, US Government Resource
- http://packetstormsecurity.com/files/172799/Delta-Electronics-InfraSuite-Device-Master-Deserialization.html
- https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02Third Party Advisory, US Government Resource