VulnerabilityModified
CVE-2022-41779
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification.
CRITICAL 9.8EPSS 1.14%
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (1.14%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.
- CVSS 3.1
- 9.8 CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- EPSS
- 1.14% probability · 65th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-502
- Affected
- deltaww/infrasuite device master
- Source
- ics-cert@hq.dhs.gov
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07Patch, Third Party Advisory, US Government Resource
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07Patch, Third Party Advisory, US Government Resource