CVE-2022-41629
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory.
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (0.63%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
- CVSS 3.1
- 9.1 CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
- EPSS
- 0.63% probability · 48th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-306
- Affected
- deltaww/infrasuite device master
- Source
- ics-cert@hq.dhs.gov
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07Patch, Third Party Advisory, US Government Resource
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07Patch, Third Party Advisory, US Government Resource
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.