SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2022-28329

A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0).

MEDIUM 6.5EPSS 0.37%

Does this matter?

Lower severity and a low EPSS score (0.37%). Track it; it rarely justifies an emergency change on its own.

Description

A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature.

CVSS 3.1
6.5 MEDIUMCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
0.37% probability · 30th percentile
CISA KEV
Not listed
Weakness
CWE-20
Affected
siemens/scalance w1788-2ia m12 firmware · siemens/scalance w1788-2 m12 firmware · siemens/scalance w1788-2 eec m12 firmware · siemens/scalance w1788-1 m12 firmware
Source
productcert@siemens.com

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.