SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2022-2759

Delta Electronics Delta Robot Automation Studio (DRAS) versions prior to 1.13.20 are affected by improper restrictions where the software processes an XML document that can contain XML entities with URIs that resolve to documents outside of the intended…

HIGH 8.6EPSS 1.16%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (1.16%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

Delta Electronics Delta Robot Automation Studio (DRAS) versions prior to 1.13.20 are affected by improper restrictions where the software processes an XML document that can contain XML entities with URIs that resolve to documents outside of the intended sphere of control, causing the product to embed incorrect documents into its output. This may allow an attacker to view sensitive documents and information on the affected host.

CVSS 3.1
8.6 HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N
EPSS
1.16% probability · 65th percentile
CISA KEV
Not listed
Weakness
CWE-611
Affected
deltaww/delta robot automation studio
Source
ics-cert@hq.dhs.gov

References

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.