VulnerabilityModified
CVE-2022-2660
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
HIGH 7.5EPSS 0.62%
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (0.62%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
- CVSS 3.1
- 7.5 HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- EPSS
- 0.62% probability · 48th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-321, CWE-798
- Affected
- deltaww/dialink
- Source
- ics-cert@hq.dhs.gov
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02Third Party Advisory, US Government Resource
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-02Third Party Advisory, US Government Resource
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.