CVE-2022-1368
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by…
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (0.94%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
- CVSS 3.1
- 9.8 CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- EPSS
- 0.94% probability · 59th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-306
- Affected
- cognex/3d-a1000 dimensioning system firmware
- Source
- ics-cert@hq.dhs.gov
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03Third Party Advisory, US Government Resource
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03Third Party Advisory, US Government Resource
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.