SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2022-1159

Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user.

HIGH 7.2EPSS 3.45%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (3.45%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user.

CVSS 3.1
7.2 HIGHCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
EPSS
3.45% probability · 88th percentile
CISA KEV
Not listed
Weakness
CWE-94
Affected
rockwellautomation/controllogix 5580 firmware · rockwellautomation/guardlogix 5580 firmware · rockwellautomation/compactlogix 5380 firmware · rockwellautomation/compactlogix 5480 firmware · rockwellautomation/compact guardlogix 5380 firmware
Source
ics-cert@hq.dhs.gov

References

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.