SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2021-20168

A malicious actor with physical access to the device is able to connect to the UART port via a serial connection, login with default credentials, and execute commands as the root user.

MEDIUM 6.8EPSS 0.33%

Does this matter?

Lower severity and a low EPSS score (0.33%). Track it; it rarely justifies an emergency change on its own.

Description

Netgear RAX43 version 1.0.3.96 does not have sufficient protections to the UART interface. A malicious actor with physical access to the device is able to connect to the UART port via a serial connection, login with default credentials, and execute commands as the root user. These default credentials are admin:admin.

CVSS 3.1
6.8 MEDIUMCVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
0.33% probability · 26th percentile
CISA KEV
Not listed
Weakness
CWE-287
Affected
netgear/rax43 firmware
Source
vulnreport@tenable.com

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.