VulnerabilityModified
CVE-2020-9045
During installation or upgrade to Software House C•CURE 9000 v2.70 and American Dynamics victor Video Management System v5.2, the credentials of the user used to perform the installation or upgrade are logged in a file.
MEDIUM 6.5EPSS 0.99%
Does this matter?
Lower severity and a low EPSS score (0.99%). Track it; it rarely justifies an emergency change on its own.
Description
During installation or upgrade to Software House C•CURE 9000 v2.70 and American Dynamics victor Video Management System v5.2, the credentials of the user used to perform the installation or upgrade are logged in a file. The install log file persists after the installation.
- CVSS 3.1
- 6.5 MEDIUMCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
- EPSS
- 0.99% probability · 61th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-312
- Affected
- tyco/victor video management system · johnsoncontrols/c-cure 9000 firmware
- Source
- productsecurity@jci.com
References
- https://www.johnsoncontrols.com/cyber-solutions/security-advisoriesPatch, Vendor Advisory
- https://www.us-cert.gov/ics/advisories/ICSA-20-142-01Third Party Advisory, US Government Resource
- https://www.johnsoncontrols.com/cyber-solutions/security-advisoriesPatch, Vendor Advisory
- https://www.us-cert.gov/ics/advisories/ICSA-20-142-01Third Party Advisory, US Government Resource
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.