VulnerabilityModified
CVE-2020-5806
An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll.
MEDIUM 5.5EPSS 4.78%
Does this matter?
Lower severity and a low EPSS score (4.78%). Track it; it rarely justifies an emergency change on its own.
Description
An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
- CVSS 3.1
- 5.5 MEDIUMCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
- EPSS
- 4.78% probability · 91th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-770
- Affected
- rockwellautomation/factorytalk linx
- Source
- vulnreport@tenable.com
References
- https://www.tenable.com/security/research/tra-2020-71Third Party Advisory
- https://www.tenable.com/security/research/tra-2020-71Third Party Advisory
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.