CVE-2020-28331
Barco wePresent WiPG-1600W devices have Improper Access Control.
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (1.69%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
Barco wePresent WiPG-1600W devices have Improper Access Control. Affected Version(s): 2.5.1.8. The Barco wePresent WiPG-1600W device has an SSH daemon included in the firmware image. By default, the SSH daemon is disabled and does not start at system boot. The system initialization scripts read a device configuration file variable to see if the SSH daemon should be started. The web interface does not provide a visible capability to alter this configuration file variable. However, a malicious actor can include this variable in a POST such that the SSH daemon will be started when the device boots.
- CVSS 3.1
- 7.5 HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
- EPSS
- 1.69% probability · 76th percentile
- CISA KEV
- Not listed
- Affected
- barco/wepresent wipg-1600w firmware
- Source
- cve@mitre.org
References
- http://packetstormsecurity.com/files/160162/Barco-wePresent-Undocumented-SSH-Interface.htmlThird Party Advisory, VDB Entry
- https://korelogic.com/Resources/Advisories/KL-001-2020-007.txtThird Party Advisory
- http://packetstormsecurity.com/files/160162/Barco-wePresent-Undocumented-SSH-Interface.htmlThird Party Advisory, VDB Entry
- https://korelogic.com/Resources/Advisories/KL-001-2020-007.txtThird Party Advisory
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.