SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2020-25178

Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.

HIGH 8.8EPSS 1.69%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (1.69%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.

CVSS 3.1
8.8 HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
EPSS
1.69% probability · 76th percentile
CISA KEV
Not listed
Weakness
CWE-319
Affected
schneider-electric/easergy t300 firmware · schneider-electric/easergy c5 firmware · schneider-electric/micom c264 firmware · schneider-electric/pacis gtw firmware · schneider-electric/saitel dp firmware · schneider-electric/epas gtw firmware · schneider-electric/saitel dr firmware · schneider-electric/scd2200 firmware · rockwellautomation/aadvance controller · rockwellautomation/isagraf free runtime · rockwellautomation/isagraf runtime · rockwellautomation/micro810 firmware · rockwellautomation/micro820 firmware · rockwellautomation/micro830 firmware · rockwellautomation/micro850 firmware · rockwellautomation/micro870 firmware · xylem/multismart firmware
Source
ics-cert@hq.dhs.gov

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.