A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16).

CRITICAL 9.8EPSS 1.48%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (1.48%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

CVSS 3.1
9.8 CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
1.48% probability · 72th percentile
CISA KEV
Not listed
Weakness
CWE-305, CWE-287
Affected
siemens/simatic hmi united comfort panels firmware