SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2020-10270

Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address.

CRITICAL 9.8EPSS 1.66%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (1.66%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.

CVSS 3.1
9.8 CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
1.66% probability · 75th percentile
CISA KEV
Not listed
Weakness
CWE-798
Affected
aliasrobotics/mir100 firmware · aliasrobotics/mir200 firmware · aliasrobotics/mir250 firmware · aliasrobotics/mir500 firmware · aliasrobotics/mir1000 firmware · mobile-industrial-robotics/er200 firmware · enabled-robotics/er-lite firmware · enabled-robotics/er-flex firmware · enabled-robotics/er-one firmware · uvd-robots/uvd robots firmware
Source
cve@aliasrobotics.com