SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2020-10049

A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2).

HIGH 7.3EPSS 0.26%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (0.26%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The start-stop scripts for the services of the affected application could allow a local attacker to include arbitrary commands that are executed when services are started or stopped interactively by system administrators.

CVSS 3.1
7.3 HIGHCVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
EPSS
0.26% probability · 18th percentile
CISA KEV
Not listed
Weakness
CWE-276
Affected
siemens/simatic rtls locating manager
Source
productcert@siemens.com

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.