CVE-2019-6843

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a…

MEDIUM 4.9EPSS 0.96%

Does this matter?

Lower severity and a low EPSS score (0.96%). Track it; it rarely justifies an emergency change on its own.

Description

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the controller with an empty firmware package using FTP protocol.

CVSS 3.1
4.9 MEDIUMCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
EPSS
0.96% probability · 60th percentile
CISA KEV
Not listed
Weakness
CWE-755
Affected
schneider-electric/modicon m580 firmware · schneider-electric/modicon m340 firmware · schneider-electric/modicon bmxcra firmware · schneider-electric/modicon 140cra firmware
Source
cybersecurity@se.com