SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2019-6585

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1).

MEDIUM 6.1EPSS 0.74%

Does this matter?

Lower severity and a low EPSS score (0.74%). Track it; it rarely justifies an emergency change on its own.

Description

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.

CVSS 3.1
6.1 MEDIUMCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
EPSS
0.74% probability · 53th percentile
CISA KEV
Not listed
Weakness
CWE-80, CWE-79
Affected
siemens/scalance s602 firmware · siemens/scalance s612 firmware · siemens/scalance s623 firmware · siemens/scalance s627-2m firmware
Source
productcert@siemens.com

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.