SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2019-6567

A vulnerability has been identified in SCALANCE X-200 switch family (incl.

MEDIUM 5.5EPSS 0.30%

Does this matter?

Lower severity and a low EPSS score (0.30%). Track it; it rarely justifies an emergency change on its own.

Description

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.

CVSS 3.1
5.5 MEDIUMCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
EPSS
0.30% probability · 23th percentile
CISA KEV
Not listed
Weakness
CWE-257, CWE-522
Affected
siemens/scalance x-200 firmware · siemens/scalance x-200irt firmware · siemens/scalance x-300 firmware · siemens/scalance x-414-3e firmware
Source
productcert@siemens.com

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.