CVE-2019-5643
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may enumerate the user names and facility…
Does this matter?
Lower severity and a low EPSS score (0.90%). Track it; it rarely justifies an emergency change on its own.
Description
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation.
- CVSS 3.1
- 5.3 MEDIUMCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
- EPSS
- 0.90% probability · 58th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-284, CWE-306
- Affected
- gatech/computing for good\'s basic laboratory information system
- Source
- cve@rapid7.com
References
- https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/Exploit, Third Party Advisory
- https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/Exploit, Third Party Advisory
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.