CVE-2019-5617
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any…
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (1.32%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
- CVSS 3.1
- 9.8 CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- EPSS
- 1.32% probability · 69th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-284, CWE-306
- Affected
- gatech/computing for good\'s basic laboratory information system
- Source
- cve@rapid7.com
References
- https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/Exploit, Third Party Advisory
- https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/Exploit, Third Party Advisory
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.