SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2019-19292

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0).

HIGH 8.8EPSS 2.00%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (2.00%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to read or modify the CCS database and potentially execute administrative database operations or operating system commands.

CVSS 3.1
8.8 HIGHCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS
2.00% probability · 80th percentile
CISA KEV
Not listed
Weakness
CWE-89
Affected
siemens/sinvr 3 central control server · siemens/sinvr 3 video server
Source
productcert@siemens.com

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.