SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2019-19276

A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl.

MEDIUM 5.3EPSS 1.02%

Does this matter?

Lower severity and a low EPSS score (1.02%). Track it; it rarely justifies an emergency change on its own.

Description

A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.

CVSS 3.1
5.3 MEDIUMCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
EPSS
1.02% probability · 61th percentile
CISA KEV
Not listed
Weakness
CWE-787
Affected
siemens/simatic hmi ktp mobile panels firmware · siemens/simatic hmi comfort panels firmware
Source
productcert@siemens.com