VulnerabilityModified
CVE-2019-19276
A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl.
MEDIUM 5.3EPSS 1.02%
Does this matter?
Lower severity and a low EPSS score (1.02%). Track it; it rarely justifies an emergency change on its own.
Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.
- CVSS 3.1
- 5.3 MEDIUMCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
- EPSS
- 1.02% probability · 61th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-787
- Affected
- siemens/simatic hmi ktp mobile panels firmware · siemens/simatic hmi comfort panels firmware
- Source
- productcert@siemens.com
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdfPatch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdfPatch, Vendor Advisory
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.