CVE-2019-18316
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2).
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (2.74%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted packets to 1099/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
- CVSS 3.1
- 9.8 CRITICALCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- EPSS
- 2.74% probability · 86th percentile
- Public exploits
- None in Exploit-DB
- CISA KEV
- Not listed
- Weakness
- CWE-502
- Affected
- siemens/sppa-t3000 application server
- Source
- productcert@siemens.com
EPSS 2.7% since 26 October 2026; no change recorded yet. Points are recorded when the score first appears and whenever it moves by a percentage point or more.
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdfMitigation, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdfMitigation, Vendor Advisory
Source: NVD record, EPSS from FIRST.org, KEV from CISA, exploits from Exploit-DB. Refreshed daily. Download this record as JSON.