SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2019-13947

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0).

MEDIUM 4.9EPSS 0.86%

Does this matter?

Lower severity and a low EPSS score (0.86%). Track it; it rarely justifies an emergency change on its own.

Description

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The user configuration menu in the web interface of the Control Center Server (CCS) transfers user passwords in clear to the client (browser). An attacker with administrative privileges for the web interface could be able to read (and not only reset) passwords of other CCS users.

CVSS 3.1
4.9 MEDIUMCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
EPSS
0.86% probability · 56th percentile
CISA KEV
Not listed
Weakness
CWE-317, CWE-312
Affected
siemens/sinvr 3 central control server · siemens/sinvr 3 video server
Source
productcert@siemens.com

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.