CVE-2019-13926
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1).
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (1.50%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.
- CVSS 3.1
- 7.5 HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- EPSS
- 1.50% probability · 73th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-400
- Affected
- siemens/scalance s602 firmware · siemens/scalance s612 firmware · siemens/scalance s623 firmware · siemens/scalance s627-2m firmware
- Source
- productcert@siemens.com
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdfVendor Advisory
- https://www.us-cert.gov/ics/advisories/icsa-20-042-10Third Party Advisory, US Government Resource
- https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdfVendor Advisory
- https://www.us-cert.gov/ics/advisories/icsa-20-042-10Third Party Advisory, US Government Resource
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.