CVE-2019-10942

A vulnerability has been identified in SCALANCE X-200 switch family (incl.

HIGH 8.6EPSS 1.36%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (1.36%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X204RNA (HSR) (All versions), SCALANCE X204RNA (PRP) (All versions), SCALANCE X204RNA EEC (HSR) (All versions), SCALANCE X204RNA EEC (PRP) (All versions), SCALANCE X204RNA EEC (PRP/HSR) (All versions). The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.

CVSS 3.1
8.6 HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
EPSS
1.36% probability · 70th percentile
CISA KEV
Not listed
Weakness
CWE-400
Affected
siemens/scalance x-200 firmware · siemens/scalance x-200irt firmware · siemens/scalance x-200rna firmware