On SRX5000 Series devices, if 'set security zones security-zone <zone> tcp-rst' is configured, the flowd process may crash when a specific TCP packet is received by the device and triggers a new session.

HIGH 7.5EPSS 1.28%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (1.28%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

On SRX5000 Series devices, if 'set security zones security-zone <zone> tcp-rst' is configured, the flowd process may crash when a specific TCP packet is received by the device and triggers a new session. The process restarts automatically. However, receipt of a constant stream of these TCP packets may result in an extended Denial of Service (DoS) condition on the device. This issue affects Juniper Networks Junos OS: 18.2R3 on SRX 5000 Series; 18.4R2 on SRX 5000 Series; 19.2R1 on SRX 5000 Series.

CVSS 3.1
7.5 HIGHCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
1.28% probability · 68th percentile