CVE-2018-4854
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions).
Does this matter?
High impact if exploited, but EPSS currently rates exploitation as unlikely (2.54%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.
Description
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the administrative client stored on the device. If a legitimate user downloads and executes the modified client from the affected device, then he/she could obtain code execution on the client system.
- CVSS 3.0
- 8.8 HIGHCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- EPSS
- 2.54% probability · 84th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-306
- Affected
- siemens/siclock tc400 firmware · siemens/siclock tc100 firmware
- Source
- productcert@siemens.com
References
- http://www.securityfocus.com/bid/104672Third Party Advisory, VDB Entry
- https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdfMitigation, Vendor Advisory
- http://www.securityfocus.com/bid/104672Third Party Advisory, VDB Entry
- https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdfMitigation, Vendor Advisory