Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to cause a denial of service by crashing the Common Industrial Protocol (CIP) network stack.

CRITICAL 9.8EPSS 5.64%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (5.64%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to cause a denial of service by crashing the Common Industrial Protocol (CIP) network stack. The vulnerability allows the attacker to crash the CIP in a way that it does not accept new connections, but keeps the current connections active, which can prevent legitimate users from recovering control.

CVSS 3.0
9.8 CRITICALCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
EPSS
5.64% probability · 93th percentile
CISA KEV
Not listed
Weakness
CWE-400
Affected
rockwellautomation/powerflex 525 ac drives firmware